Nyuda impact wiwitan lan gangguan: Water Pump Motor Soft Starter karo Bypass Inside mboko sithik menehi voltase wiwitan kanggo motor pump banyu, nyegah arus gedhe banget lan ngurangi impact lan gangguan nalika wiwitan, nglindhungi peralatan mechanical lan kothak daya.
Water Pump Motor Soft Starter karo Bypass Nang
- Nyuda impact wiwitan lan gangguan: Starter alus mboko sithik menehi voltase wiwitan kanggo motor pump banyu, nyegah arus gedhe banget lan ngurangi impact lan gangguan nalika wiwitan, nglindhungi peralatan mechanical lan kothak daya.
- Ngurangi tingkat kegagalan: Nggunakake starter alus motor pompa banyu bisa nambah umur peralatan lan nyuda tingkat kegagalan.
- Njamin proses wiwitan sing lancar: Starter alus njamin pasokan daya sing lancar lan bertahap sajrone wiwitan, ngidini akeh wektu kanggo persiapan sadurunge motor diwiwiti.
- Ngirit energi nalika wiwitan: Starter alus motor pompa banyu nyuda konsumsi energi kanthi nyilikake kabutuhan switch udara lan unsur listrik kanthi kapasitas gedhe.
- Fitur bypass nang: wiwitan alus iki dilengkapi fungsi bypass, ngidini kanggo operasi trep lan pangopènan.
Menu Utama |
Sub Menu |
Paramèter |
A. S&P Kanggo |
A00.Curr Limit kanggo CLS |
10%~500% |
A01.Init Volt kanggo VRS |
30%~80% |
|
A02.Wiwiti Wektu kanggo VRS |
1~120s |
|
A03.Volt kanggo Plus Mulai |
30%~80% |
|
A04.Wektu kanggo Plus Mulai |
0~500ms |
|
A05.Curr Limit kanggo CRS |
10%~400% |
|
A06.Wiwiti Wektu kanggo CRS |
1~120s |
|
A07.Volt kanggo Hukum |
30%~80% |
|
A08.Wektu kanggo Soft Stop |
1~10s |
|
A09. Wiwiti Mode |
Mantan Ramp Limit Curr Jog Curug Ramp Plus & Ramp C-Limit Ramp |
|
A10. Mode Mungkasi |
Free Stop Soft Stop |
|
A11. Mode Kontrol |
Larang Papan ketik Terminal Ctrl Istilah & Kunci |
|
A12.Prog Relay Func |
Non-Fungsi Power On siyaga miwiti Bypass mandheg mlaku Fault |
|
B. Nglindhungi |
B00. Rasio OC Mulai |
400%~600% |
B01.Running OC Ratio |
200%~400% |
|
B02. Miwiti OL Level |
1~8 |
|
B03.Mlaku OL Level |
1~8 |
|
B04. Curr Unbalance Ratio |
5%~85% |
|
B05. Luwih Ambang Volt |
100%~140% |
|
B06. Ing Ambang Volt |
60%~100% |
|
B07. Ing Ambang Beban |
0%~100% |
|
B08.Under Load Tundha |
0~200s |
|
C. Mlayu menyang |
C00. Starter Rated Curr |
Pabrik Konstan |
C01. Starter Rated Volt |
Pabrik Konstan |
|
C02.Motor Rated Curr |
5A~ Wiwitan Dirating Curr |
|
C03. Curr Cali Ratio |
50~1500 |
|
C04.Pulse Under Running |
Pulsa Ora Pulsa |
|
D. Liyane |
D00.MODBUS Addr |
1~127 |
D01.Baud Rate |
19200 9600 4800 2400 1200 |
|
D02. Sistem Volt Cal |
5~200 |
|
D04.Basa |
Cina Inggris Rusian |